Technical Data

Comprehensive technical specifications for INCOM Rockwool products

 

TECHNICAL DATA

The following technical information presents typical/reference properties of INCOM Rockwool insulation products. Final values may vary according to product density, thickness, facing, test method and specific product configuration.

Chemical Composition

Chemical ComponentTypical Range
SiO₂42–50%
Al₂O₃10–17%
Fe₂O₃7–14%
TiO₂1–13%
CaO6–15%
MgO6–14%
Na₂O2–3%
K₂O0.5–3%

Physical Properties

Physical PropertiesTypical Value
Diameter of Fibres4–10 micron
Length of FibresAverage 200 mm
Shot Content (0.2 mm mesh)Maximum 15%
Loss on Ignition0%
Water Content0%
Sulfur Content0%
Asbestos Content0%
Air Permeability70 / 100 / 140 kg/CM (as specified)

Thermal Conductivity

INCOM Rockwool products offer low thermal conductivity. Thermal conductivity varies with the density of the product and the mean temperature of the insulation. The graph below presents typical reference values for Rockwool Mattress at different densities and mean temperatures.

chart-new

The thermal conductivity curve is based on reference measurements made using a guarded hot-plate apparatus in accordance with BS 874:1973 and DIN 52 612 Part 1. Actual values may vary with density, facing, test method and product details.

Corrosion Resistance

INCOM Rockwool products are faintly alkaline and are not corrosive to steel under normal application conditions. When tested in accordance with BS 3958, Rockwool products have a pH of approximately 7.5 to 8.0 and contain less than 7 p.p.m. soluble chlorides, complying with the referenced ASTM C 795 requirements.

Flammability / Fire Performance

INCOM Rockwool is a non-combustible mineral wool insulation material and has been specified with reference to DIN 4102 Class A and BS 476 fire-performance requirements. Rockwool has a high fusion temperature, reported in excess of 1,150°C under fire conditions, and can provide an effective barrier against heat and flames when correctly selected and installed.

Compression Resistance

INCOM Rockwool Mattresses are designed primarily for flexibility. They nevertheless provide good compression resistance and dimensional stability under normal compression loads. Compression performance depends on density, thickness, product construction and loading conditions. Wired Rockwool Mattress can be used where additional mechanical support is required.

Moisture Resistance

Rockwool is a water-repellent yet porous insulation material. Under normal conditions it does not readily absorb water; however, water can enter the fibre structure when material is subjected to pressure or forced immersion. When the pressure is removed and the product is allowed to dry, its insulation performance can recover. Referenced testing to BS 2972 indicates typical moisture absorption of approximately 1–3 volume percent.

Acoustic Properties

Rockwool is widely used for acoustic control in buildings and industrial environments. Its open fibrous structure absorbs sound energy and helps reduce noise transmission and reverberation. It can be used for acoustic treatment of walls, ceilings, ducts, equipment enclosures and other applications where sound attenuation is required.